Container
• Each SiteVault module is either a 20ft (6.1m) or 40ft (12.2m)insulated steel container
• Frame: anti corrosion weather resistant corten steel
• Outer panels: galvanised steel sheets for anti corrosion protection
• External colour: painted white to reduce solar radiation affect
• Inner roof and side panels: pre-painted white steel sheets for high light reflectivity
• Inner insulated floor: aluminium chequer plate floor for anti slip and easy cleaning

Capacity
• 20ft unit (approx): 850 cubic ft (24 cubic metres)
• 40ft unit (approx): 2,200 cubic ft (62 cubic metres)

Dimensions and Ratings (40ft unit)
• External length: 12,192mm/40ft
• External width: 2,438mm/8ft
• External height: 2,591mm/8ft 6ins
• Max gross weight: 20,000kg/44092lbs
• Tare weight (excluding unit): 3,800kg/8378lbs
• Machinery: 287kg/633lbs

Dimensions and Ratings (20ft unit)
• External length: 6,096mm/20ft
• External width: 2,438mm/8ft
• External height: 2,591mm/8ft 6ins
• Max gross weight: 12,000kg/26,453lbs
• Tare weight (excluding unit): 3,330kg/7,340lbs
• Machinery: 200kg/440lbs

Refrigeration Machinery
• Machinery type: Zanotti SAS 335
• Voltage: three-phase and neutral plus earth, five wire plug.
   440 volts/three-phase/50hz
• Nominal power: 3.7 Kw
• Maximum power: 5.6 Kw
• Current: 15 amps
• Power supply required: 32 amps, 3 phase, neutral and earth
• Machinery weight: 249kg
• Temperature control range: -5C to +15C
• Humidity control range: 25% to 40% relative humidity
• Refrigerant: R404A

Security
• Door openings can be set to act as a burglar alarm
• Remote monitoring online. Features include:
  – Standard system can monitor and record delivery/supply air temperature; return      air temperature; ambient air temperature; two cargo temperatures; humidity and      power failure
  – Data uploaded and stored every ten minutes
  – Data presented in graphical or numerical format
  – Alarm trigger points can be set
  – Activated alarms can trigger automatic response and call out

Noise
Decibel levels are between 45 and 51 dbs

Built-in Redundancy
Adjacent containers have interconnecting fans providing back up in the event of technical failure